Osram PrevaLED Core Z2 Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
18
THERMAL CONSIDERATIONS
Recommended thermocouples
Description Temperature [°C] Length [mm]
Thermal probe -10…+100
2000
cable
Adhesive foil probe -50…+250
1000
wire
All figures in mm
4.4. Thermal simulation
Using a computer, matching heat sink housing forms and
occurring maximum temperatures can be calculated by
means of numerical heat simulation.
Two thermo simulation examples:
T heat sink:
38…41 °C
T heat sink:
46…49 °C
T ambient: 25 °C
T ambient: 25 °C
Surface area ~ 0.5 m
2
(P 200 84 Meccal)
Surface area ~ 0.25 m
2
(P115 80 Meccal)
T
C
: 39 °C
T
C
: 47 °C
PrevaLED
®
LEP-2100 on heat sink with extruded profi le
150 mm in downlight orientation
3D fi les for thermal simulation can be found at:
www.osram.com/prevaled-core.
Thermal model description:
PrevaLED
®