Instruction and Safety advice for OUTKIT version 30 x 30
The housing is developed for electronic control gear (ECG) of OSRAM in a cross section of 30 x 30 mm in order
to reliably protect the ECG of humidity in IP67. OUTKIT
30 short is intended to protect 1lamp ECG in the
dimension of 360 x 30 x 30 mm and OUTKIT
30 long to protect 2lamp ECG in the dimensions of 423 x 30 x 30
mm . OUTKIT consists of the square pipe (1) , two pre-assembled screw caps out of single parts numbers 2, 3, 5
and 7 and bulk enclosed seal inserts for the use of single wires and 2 pcs. of caps (6).
To ensure reliable operation in IP 67 it is necessary that you follow the construction and safety information as
below:
Assembly instructions:
To mount the cable screw you need tools with a wrench size 22.
Within OUTKIT the ECG can be mounted with single wires or / and special ÖLFLEX 400P or 540P of
company U.I.Lapp GmbH www.lappgroup.com
Please see below the tested and approved types of cables and single wires:
OUTKIT 30 short
Input side Lamp side
wires
ÖLFLEX CLASSIC 400 P 2 x 0.75 or 540 P 2x 0.75
for PC II and ÖLFLEX CLASSIC 400 P 3 G 0.75 or
540 P 3G 0.75 for PC I
ÖLFLEX CLASSIC
400 P 4 x 0.75
single wires
H 05 V , max. diameter of 3 mm incl. a seal insert 2x3
or 3x3
H05 V , max. diameter of 3 mm incl. seal
insert 4x3
OUTKIT 30 long
Input side Lamp side
wires
ÖLFLEX CLASSIC 400 P 2 x 0.75 or 540 P 2x 0.75
for PC II and ÖLFLEX CLASSIC 400 P 3 G 0.75 or
540 P 3G 0.75 for PC I
ÖLFLEX CLASSIC
400 P 7 x 0.75
single wires
H 05 V, max. diameter of 3 mm incl. a seal insert 2x3
or 3x3
H 05 V, max. diameter of 2.7 mm incl. a seal
insert 7x2.7
For the use of dimmable ECG you must use 2 additional wires at the Input Side.
ÖLFLEX CLASSIC 400 P 4x0.75 for PC I and 400 P 5 G 0.75 or 540 P 5 G 0.75 for PC II.
The cover caps (6) are put from outside into the two vents at the end of the ECG and secure the positioning
of the ECG within the square pipe
Press the cover caps to the joint of the square pipe and secure it with the tools of the wrench size 22:
Safety instruction:
1. No guarantee for the type of protection of the system if you use different cable manufacturer.
2. If you use OUTKIT as a semiluminaire for lamps and for different light sources as well as for the use of different
ECG brands we do not
take any responsibility.